SAP BW Maintanance problems


S.No
Error
Explanation
Solution
1
ODS Activation problem
Though the ODS is active and data is available in the active table. Sometimes the data loaded data into ODS is not available for reporting
Right click on ODS and choose Activate the ODS data.
2
Bad records in PSA
When Illegal characters are loaded
Correct the illegal characters
3
ODS to cube load failure
Though during the built of ODS if we set under settings ‘update data targets automatically’, sometimes the data is not available to the target cube.
Right click on ODS Object and choose ‘Update data into data target’
4
Loading data using process chains
When load is in progress using process chains to a particular data source. If a user tries to create a record to that data source then the load gets stooped.

5
Error message when processing in business information warehouse
The result of this step is short dump.
Load the data from PSA.
6
Definition
After crating the ODS, when we try to activate the ODS it will not get activated because of problem in RFC
Rectify the problem in RFC destination
7
RFC connection check failed
When transferring the data from one level of ODS to next level of ODS, the data will not be transferred to second level ODS
In monitor under details check in subsequent processing and check for RFC connection problem and rectify the problem.